Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Reader Login
  Home Print this page Email this page Small font sizeDefault font sizeIncrease font size Users Online: 757  
Export selected to
Endnote
Reference Manager
Procite
Medlars Format
RefWorks Format
BibTex Format
  Access statistics : Table of Contents
   2015| September-December  | Volume 14 | Issue 3  
    Online since August 20, 2015

 
 
  Archives   Previous Issue   Next Issue   Most popular articles   Most cited articles
 
Hide all abstracts  Show selected abstracts  Export selected to
  Viewed PDF Cited
ORIGINAL ARTICLES
Modified PISAPED Criteria in Combination with Ventilation Scintigraphic Finding for Predicting Acute Pulmonary Embolism
Naoyuki Watanabe, Jure Fettich, Nurie Özlem Küçük, Otakar Kraft, Fernando Mut, Partha Choudhury, Surendra K Sharma, Keigo Endo, Maurizio Dondi
September-December 2015, 14(3):178-183
DOI:10.4103/1450-1147.163248  PMID:26420988
This prospective clinical study aimed at assessing three pulmonary scintigraphic algorithms to detect acute pulmonary embolism (PE): Lung ventilation/perfusion (V/Q) scintigraphy along with modified prospective investigation of pulmonary embolism diagnosis (PIOPED) criteria; lung perfusion scintigraphy along with prospective investigative study of acute pulmonary embolism diagnosis (PISAPED) criteria; and lung perfusion scan in combination with ventilation scan, along with modified PISAPED criteria, which were newly developed. Patients with suspicion of PE were eligible for this study if they had no abnormal chest x-ray. Their diagnostic workup included a clinical assessment, a pulmonary V/Q scintigraphy, and CT pulmonary angiography (CTPA), as well as a clinical outcome assessment over a period of 24 weeks. Referred to the final clinical diagnosis of patients, the sensitivity and specificity of each algorithm were evaluated. The diagnostic performance of each algorithm by the area under the maximum likelihood fitted receiver operating characteristic (ROC) curve was determined. With respect to the PISAPED criteria, the sensitivity was 60.8% and specificity was 87.3%. No patient was classified into nondiagnostic category. The PIOPED criteria showed that the sensitivity was 95.0% and specificity was 88.2%, while 57.4% of the patients were in nondiagnostic category. The areas under the ROC curve constructed from the PISAPED criteria results and the modified PIOPED criteria results were 0.734 and 0.859 (P < 0.01), respectively. The modified PISAPED criteria demonstrated that the sensitivity was 83.8% and specificity was 89.1%. No patient was classified into nondiagnostic category. The area under the ROC curve constructed from modified PISAPED criteria was 0.864 (P < 0.01). Perfusion scans used with ventilation scans and modified PISAPED criteria may increase the diagnostic accuracy of pulmonary scintigraphy for acute PE, compared with the two major algorithms.
  5,087 520 4
Designing of High-Volume PET/CT Facility with Optimal Reduction of Radiation Exposure to the Staff: Implementation and Optimization in a Tertiary Health Care Facility in India
Ashish Kumar Jha, Abhijith Mohan Singh, Sneha Mithun, Sneha Shah, Archi Agrawal, Nilendu C Purandare, Bhakti Shetye, Venkatesh Rangarajan
September-December 2015, 14(3):189-196
DOI:10.4103/1450-1147.163252  PMID:26420990
Positron emission tomography (PET) has been in use for a few decades but with its fusion with computed tomography (CT) in 2001, the new PET/CT integrated system has become very popular and is now a key influential modality for patient management in oncology. However, along with its growing popularity, a growing concern of radiation safety among the radiation professionals has become evident. We have judiciously developed a PET/CT facility with optimal shielding, along with an efficient workflow to perform high volume procedures and minimize the radiation exposure to the staff and the general public by reducing unnecessary patient proximity to the staff and general public.
  4,657 535 1
REVIEW ARTICLES
Radioiodine Remnant Ablation: A Critical Review
Chandra Sekhar Bal, Ajit Kumar Padhy
September-December 2015, 14(3):144-155
DOI:10.4103/1450-1147.163240  PMID:26420983
Radioiodine remnant ablation (RRA) is considered a safe and effective method for eliminating residual thyroid tissue, as well as microscopic disease if at all present in thyroid bed following thyroidectomy. The rationale of RRA is that in the absence of thyroid tissue, serum thyroglobulin (Tg) measurement can be used as an excellent tumor marker. Other considerations are like the presence of significant remnant thyroid tissue makes detection and treatment of nodal or distant metastases difficult. Rarely, microscopic disease in the thyroid bed if not ablated, in the future, could be a source of anaplastic transformation. On the other hand, microscopic tumor emboli in distant sites could be the cause of distant metastasis too. The ablation of remnant tissue would in all probability eliminate these theoretical risks. It may be noted that all these are unproven contentious issues except postablation serum Tg estimation that could be a good tumor marker for detecting early biochemical recurrence in long-term follow-up strategy. Radioactive iodine is administered as a form of "adjuvant therapy" for remnant ablation. There have been several reports with regard to the administered dose for remnant ablation. The first report of a prospective randomized clinical trial was published from India by a prospective randomized study conducted at the All India Institute of Medical Sciences, New Delhi in the year 1996. The study reported that increasing the empirical 131 I initial dose to more than 50 mCi results in plateauing of the dose-response curve and thus, conventional high-dose remnant ablation needs critical evaluation. Recently, two important studies were published: One from French group and the other from UK on a similar line. Interestingly, all three studies conducted in three different geographical regions of the world showed exactly similar conclusion. The new era of low-dose remnant ablation has taken a firm scientific footing across the continents.
  3,679 745 5
Development of Scintillators in Nuclear Medicine
Mohammad Khoshakhlagh, Jalil Pirayesh Islamian, Seyed Mohammad Abedi, Babak Mahmoudian
September-December 2015, 14(3):156-159
DOI:10.4103/1450-1147.163241  PMID:26420984
High-quality image is necessary for accurate diagnosis in nuclear medicine. There are many factors in creating a good image and detector is the most important one. In recent years, several detectors are studied to get a better picture. The aim of this paper is comparison of some type of these detectors such as thallium activated sodium iodide bismuth germinate cesium activated yttrium aluminum garnet (YAG: Ce) YAP: Ce "lutetium aluminum garnet activated by cerium" CRY018 "CRY019" lanthanum bromide and cadmium zinc telluride. We studied different properties of these crystals including density, energy resolution and decay times that are more important factors affecting the image quality.
  2,900 486 6
ORIGINAL ARTICLES
Dose Calibrator Linearity Testing: Radioisotope 99mTc or 18F? An Alternative for Reducing Costs in Nuclear Medicine Quality Control
José Willegaignon, Marcelo T Sapienza, George Barberio Coura-Filho, Alexandre T Garcez, Carlos E Alves, Marissa R Cardona, Ricardo F Gutterres, Carlos A Buchpiguel
September-December 2015, 14(3):165-170
DOI:10.4103/1450-1147.163245  PMID:26420986
Dose calibrator linearity testing is indispensable for evaluating the capacity of this equipment in measuring radioisotope activities at different magnitudes, a fundamental aspect of the daily routine of a nuclear medicine department, and with an impact on patient exposure. The main aims of this study were to evaluate the feasibility of substituting the radioisotope Fluorine-18 ( 18 F) with Technetium-99m ( 99m Tc) in this test, and to indicate it with the lowest operational cost. The test was applied with sources of 99m Tc (62 GBq) and 18 F (12 GBq), the activities of which were measured at different times, with the equipment preadjusted to measuring sources of 99m Tc, 18 F, Gallium-67 ( 67 Ga), and Iodine-131 ( 131 I). Over time, the average deviation between measured and expected activities from 99m Tc and 18 F were, respectively, 0.56 (±1.79)% and 0.92 (±1.19)%. The average ratios for 99 m Tc source experimental activity, when measured with the equipment adjusted for measuring 18 F, 67 Ga, and 131 I sources, in real values, were, respectively, 3.42 (±0.06), 1.45 (±0.03), and 1.13 (±0.02), and those for the 18 F source experimental activity, measured through adjustments of 99m Tc, 67 Ga, and 131 I, were, respectively, 0.295 (±0.004), 0.335 (±0.007), and 0.426 (±0.006). The adjustment of a simple exponential function for describing 99m Tc and 18 F experimental activities facilitated the calculation of the physical half-lives of the radioisotopes, with a difference of about 1% in relation to the values described in the literature. Linearity test results, when using 99m Tc, through being compatible with those acquired with 18 F, imply the possibility of using both radioisotopes during linearity testing. Nevertheless, this information, along with the high potential of exposure and the high cost of 18 F, implies that 99m Tc should preferably be employed for linearity testing in clinics that normally use 18 F, without the risk of prejudicing either the procedure itself or the guarantee of a high-quality nuclear medicine service.
  2,622 383 1
The Effect of Parallel-hole Collimator Material on Image and Functional Parameters in SPECT Imaging: A SIMIND Monte Carlo Study
Ahmadreza Azarm, Jalil Pirayesh Islamian, Babak Mahmoudian, Esmaeil Gharepapagh
September-December 2015, 14(3):160-164
DOI:10.4103/1450-1147.163242  PMID:26420985
The collimator in single-photon emission computed tomography (SPECT) is a critical component of the imaging system and plays an impressive role in the imaging quality. In this study, the effect of the collimator material on the radioisotopic image and its functional parameters was studied. The simulating medical imaging nuclear detectors (SIMIND) Monte Carlo program was used to simulate a Siemens E.CAM SPECT (Siemens Medical Solutions, Erlangen, Germany) system equipped with a low-energy high-resolution (LEHR) collimator. The simulation and experimental data from the SPECT imaging modality using 99m Tc were obtained on a point source and Jaszczak phantom. Seventeen high atomic number materials were considered as LEHR collimator materials. In order to determine the effect of the collimator material on the image and functional parameters, the energy resolution, spatial resolution, contrast, and collimator characteristics parameters such as septal penetration and scatter-to-primary ratio were investigated. Energy spectra profiles, full width at half maximums (FWHMs) (mm) of the point spread function (PSF) curves, system sensitivity, and contrast of cold spheres of the Jaszczak phantom for the simulated and experiment systems have acceptability superimposed. The results of FWHM and energy resolution for the 17 collimators showed that the collimator made of 98% lead and 2% antimony could provide the best FWHM and energy resolution, 7.68 mm and 9.87%, respectively. The LEHR collimator with 98% lead and 2% antimony offers the best resolution and contrast when compared to other high atomic number metals and alloys.
  2,563 307 1
CASE REPORTS
Colorectal Cancer with Uncommon Metastatic Spread
Luca Dellavedova, Anna Calcagno, Lucia Roncoroni, Lorenzo Stefano Maffioli
September-December 2015, 14(3):219-221
DOI:10.4103/1450-1147.161726  PMID:26420997
The prevalence of bone metastases from colorectal cancer (CRC) is quite low and the presence of isolated osseous metastases at the time of diagnosis or the onset of bone metastases without other organ involvement during follow-up is even lower. Here, we present an interesting case of diffuse skeletal metastases from CRC in which both the atypical presentation of the metastatic spread and the presence of infective comorbidities created some troubles in getting the final diagnosis.
  2,544 184 2
Radiosynovectomy of Proximal Interphalangeal Joint Synovitis in Rheumatoid Arthritis Treated with Rhenium-188 Labeled Tin-colloid and Imaging with Single-photon Emission Computerized Tomography/Computed Tomography: A First Case Report
Koramadai Karuppusamy Kamaleshwaran, Venkataraman Rajamani, Boopathi Krishnan, Madhav Mallia, Radhakrishnan Kalarikal, Vyshakh Mohanan, Ajit Sugunan Shinto
September-December 2015, 14(3):216-218
DOI:10.4103/1450-1147.161730  PMID:26420996
Rheumatoid arthritis (RA) is a chronic disease that is mainly characterized by the asymmetric erosive synovitis, particularly affecting peripheral joints. Radiation synovectomy or radiosynovectomy (RSV), also known as radiosynoviorthesis was first described in 1950's as an adjuvant treatment for RA. RSV is based on the irradiation of the joint synovium by the intra-articular administration of various β-emitting radiopharmaceuticals. As a generator-produced β-emitting radionuclide, the importance of rhenium-188 (Re-188) for radionuclide therapy is increasing rapidly. There are previous reports which used Re-188 tin colloid in knee joint synovitis, but use of Re-188 tin colloid in small joint is not yet reported. We describe the use of Re-188 tin colloid in a 45-year-old female who presented with right 4 th proximal interphalangeal joint synovitis due to rheumatoid arthritis.
  2,453 240 4
ORIGINAL ARTICLES
The Relationship Between Some Complete Blood Count Parameters and Myocardial Perfusion: A Scintigraphic Approach
Semra Ozdemir, Ahmet Barutcu, Emine Gazi, Yusuf Ziya Tan, Hakan Turkon
September-December 2015, 14(3):197-201
DOI:10.4103/1450-1147.163253  PMID:26420991
Recent studies have shown that there is a relationship between some inflammatory and biochemical markers derived from complete blood count (CBC) such as neutrophil/lymphocyte (N/L) ratio, platelet/lymphocyte (P/L) ratio, platelet distribution width (PDW), red blood cell distribution width (RDW), and coronary artery disease (CAD). The aim of this study was to determine N/L ratio, P/L ratio, PDW values, and RDW values, which are associated with myocardial perfusion in patients diagnosed with CAD. This study included 262 patients (149 with myocardial ischemia/infarction and 113 with normal myocardial perfusion) undergoing myocardial perfusion scintigraphy (MPS) with CBC within 90 days of MPS. Myocardial perfusion parameters such as summed stress score and summed difference score (SDS) were compared with N/L ratio, P/L ratio, PDW values, and RDW values. Neutrophil counts and N/L ratios were significantly higher in patients diagnosed with myocardial ischemia and/or infarct. However, there was no statistically significant relationship between myocardial perfusion abnormalities and P/L ratio, PDW values, and RDW values. This study showed that N/L ratio is related to myocardial ischemia/infarction and correlated to left ventricular ejection fraction (LVEF).
  2,327 290 1
CASE REPORTS
Lynch Syndrome Associated Colon Adenocarcinoma Resembling Lymphoma on Fluoro-Deoxyglucose-Positron Emission Tomography/Computed Tomography
Carina Mari Aparici, Aung Zaw Win
September-December 2015, 14(3):222-224
DOI:10.4103/1450-1147.161728  PMID:26420998
The patient was a 46-year-old Asian male diagnosed with lynch syndrome associated colon adenocarcinoma in the right ascending colon. A presurgical staging 18-fluoro-deoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) found increased metabolic activity in the cervical, axillary, mediastinal, supraclavicular, para-aortic and mesenteric lymph nodes. This pattern of metastasis was very unusual for lynch syndrome associated colon adenocarcinoma and the involvement of those lymph nodes resembles the pattern of spread of lymphoma. He underwent right hemicolectomy and he was subsequently treated with 12 cycles of folinic acid (leucovorin), fluorouracil (5-FU), irinotecan. A restaging FDG-PET/CT at the end of the chemotherapy showed interval decrease in size and metabolic activity in the affected lymph nodes. FDG-PET/CT is a useful imaging modality in following-up the treatment response in colon adenocarcinoma.
  2,452 164 -
Nuclear Medicine to Evaluate Complications of Cerebral Shunts: Two Cases and Review of Literature
Beth Vettiyil, Sabrina Bessette, Samuel McQuiston, Francis Greiner
September-December 2015, 14(3):212-215
DOI:10.4103/1450-1147.163263  PMID:26420995
We present two cases of cerebral shunts - a ventriculopleural shunt and a ventriculoperitoneal shunt, with their associated complications. We also hope to provide a comprehensive literature review on various imaging modalities, including nuclear medicine studies in evaluating cerebral shunt complications.
  2,375 173 1
Indium-111 Capromab Pendetide (ProstaScint®) Demonstrates Renal Cell Carcinoma and Aortocaval Nodal Metastases from Prostate Adenocarcinoma
Tanvir Rizvi, Chunli Deng, Patrice K Rehm
September-December 2015, 14(3):209-211
DOI:10.4103/1450-1147.163259  PMID:26420994
A 62-year-old male with a history of radical prostatectomy for a Gleason 9 (4 + 5) pT3N0Mx prostate cancer presented with rising prostate-specific antigen of 9.0 ng/dl. A contrast-enhanced computerized tomography (CT) revealed an enhancing left upper pole renal mass and aortocaval lymph nodes. Indium (In)-111 Capromab Pendetide (ProstaScint ® ) single-photon emission computerized tomography-CT showed abnormal increased uptake in left renal mass and aortocaval lymph nodes with no uptake in the prostate bed or pelvic lymph nodes. He underwent left radical nephrectomy and dissection of aortocaval lymph nodes. Pathology showed renal clear cell carcinoma and metastatic prostate adenocarcinoma involving aortocaval lymph nodes. Our case demonstrates a rare combination of two different malignancies, prostate cancer and clear cell renal cell cancer, showing In-111 ProstaScint ® uptake. Though ProstaScint ® uptake in renal cell carcinoma and in metastatic aortocaval lymph nodes from prostate cancer may be seen in clinical practice, this combination has not been reported previously.
  2,265 168 1
ORIGINAL ARTICLES
Is there a Role for Gallium-67 Citrate SPECT/CT, in Patients with Renal Impairment or Who are Renal Transplant Recipients, in Identifying and Localizing Suspected Infection?
Ewa Nowosinska, Shaunak Navalkissoor, Ann Marie Quigley, John R Buscombe
September-December 2015, 14(3):184-188
DOI:10.4103/1450-1147.163250  PMID:26420989
To assess the added value of single-photon emission computed tomography/computed tomography (SPECT/CT) in patients with end-stage renal failure (ESRF) or renal transplant recipients in whom focal infection was suspected. Gallium-67 (Ga-67) citrate scintigrams of 18 patients (10 in ESRF and eight with renal transplants) were reviewed. Sites of abnormal uptake seen on the whole body and SPECT were noted. A SPECT/CT was also reviewed to see if additional information could be obtained. Imaging results were compared with the final diagnosis. Overall, 14 out of 18 (78%) patients had a proven cause to explain symptoms while four patients did not have a final cause identified. Infection was proven in the final diagnosis in 12 out of 14 (86%) patients. Of the 10 patients with ESRF, six had confirmed infection with the Ga-67 citrate study correctly identifying five out of six (83%) patients, and SPECT/CT providing additional information in four out of five (80%) patients. In the eight renal transplant recipients, six had a confirmed source of infection (all identified by the Ga-67 citrate study). SPECT/CT provided additional information in two out of six (33%) patients. Ga-67 citrate imaging had an overall sensitivity of 13/14 (93%), with one false negative. SPECT/CT provided an additional contribution in eight out of 18 (44%) patients by better defining the location/extent of infection and differentiating the physiological from the pathological uptake.
  2,162 234 4
CASE REPORTS
Os Trigonum - Sheer Incidental or Quite Significant? Single Photon Emission Computed Tomography/Computed Tomography's Role in a Case of Ankle Impingement
Kabilan Chokkappan, Sivasubramanian Srinivasan, Manickam Subramanian, Anbalagan Kannivelu
September-December 2015, 14(3):205-208
DOI:10.4103/1450-1147.163257  PMID:26420993
Accessory ossicles are widely prevalent in the ankle and foot. Although they are often asymptomatic, they can present clinically with symptoms at times. When they occur bilaterally in a patient who presents with unilateral complaints, it is clinically difficult to attribute the symptoms to the presence of these common anatomic variants. One needs specific imaging to assess the clinical relevance of the accessory ossicles, in order to tailor the treatment plan. The case presented in this article is one such example, where the patient presented with chronic unilateral ankle pain and initial radiographs revealed bilateral os trigonum and os subtibiale. He underwent a technetium-99m methyl diphosphonate (Tc-99m MDP) bone scan and single photon emission computed tomography/computed tomography (SPECT/CT). The Tc-99m MDP scan showed a focal uptake in the ankle of concern. SPECT/CT complemented the finding by exactly localizing the uptake to the posterior subtalar joint and around the os trigonum, thereby pointing to the diagnosis of os trigonum syndrome.
  2,095 226 4
EDITORIAL
Not for the Last Time that I do Something for the First Time: A Time to Padhy!
Ajit S Shinto
September-December 2015, 14(3):143-143
DOI:10.4103/1450-1147.163239  PMID:26420982
  1,846 255 -
LETTER TO EDITOR
Segmental Considerations in Colonoscopy Recommendations for Investigating Focal Colonic FDG Activity on PET/CT
Joseph C Lee, Gemma F Hartnett, Aravind S Ravi Kumar
September-December 2015, 14(3):225-225
DOI:10.4103/1450-1147.161725  PMID:26420999
  1,923 122 -
CASE REPORTS
V/Q Matched Defect Larger than Hiatal Hernia Itself
Jason W Wachsmann, Chun K Kim
September-December 2015, 14(3):202-204
DOI:10.4103/1450-1147.163255  PMID:26420992
We present the case report of a patient 83 year old female who developed progressive shortness of breath and subsequently underwent scintigraphic evaluation of her symptoms with a ventilation/perfusion scintigraphic exam. A matched perfusion defect was seen involving the basal segments of the left lower lobe. Following this, the patient was examined with a contrast enhanced CT of the chest to further investigate the defect, which revealed compression of the bronchi and vasculature of the left lower lobe basal segments by the hernia larger than the actual hernia. To our knowledge there has not been a case report of a large hiatal hernia as a cause of matched lower lobe defect.
  1,786 165 -
ORIGINAL ARTICLES
Improving 18F-Fluoro-D-Glucose-Positron Emission Tomography/Computed Tomography Imaging in Alzheimer's Disease Studies
Karin Knešaurek
September-December 2015, 14(3):171-177
DOI:10.4103/1450-1147.163246  PMID:26420987
The goal was to improve Alzheimer's 2-deoxy-2- 18 F-fluoro-D-glucose ( 18 F FDG)-positron emission tomography (PET)/computed tomography (CT) imaging through application of a novel, hybrid Fourier-wavelet windowed Fourier transform (WFT) restoration technique, in order to provide earlier and more accurate clinical results. General Electric Medical Systems downward-looking sonar PET/CT 16 slice system was used to acquire studies. Patient data were acquired according the Alzheimer's disease Neuroimaging Initiative (ADNI) protocol. Here, we implemented Fourier-wavelet regularized restoration, with a Butterworth low-pass filter, order n = 6 and a cut-off frequency f = 0.35 cycles/pixel and wavelet (Daubechies, order 2) noise suppression. The original (PET-O) and restored (PET-R) ADNI subject PET images were compared using the Alzheimer's discrimination analysis by dedicated software. Forty-two PET/CT scans were used in the study. They were performed on eleven ADNI subjects at intervals of approximately 6 months. The final clinical diagnosis was used as a gold standard. For three subjects, the final clinical diagnosis was mild cognitive impairment and those 13 PET/CT studies were not included in the final comparison, as the result was considered as inconclusive. Using the reminding 29 PET/CT studies (23 AD and 6 normal), the sensitivity and specificity of the PET-O and PET-R were calculated. The sensitivity was 0.65 and 0.96 for PET-O and PET-R, respectively, and the specificity was 0.67 and 0.50 for PET-O and PET-R. The accuracy was 0.66 and 0.86 for PET-O and PET-R, respectively. The results of the study demonstrated that the accuracy of three-dimensional brain F-18 FDG PET images was significantly improved by Fourier-wavelet restoration filtering.
  709 11 2
  Feedback 
  Subscribe