Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
  Home Print this page Email this page Small font sizeDefault font sizeIncrease font size Users Online: 990  
ORIGINAL ARTICLE
Year : 2019  |  Volume : 18  |  Issue : 3  |  Page : 251-257

Quantitative comparison between single-photon emission computed tomography and positron emission tomography imaging of lung ventilation with 99mTc-technegas and 68Ga-gallgas in patients with chronic obstructive pulmonary disease: A pilot study


1 Physics Institute, Sciences Faculty, UDELAR, Montevideo, Uruguay
2 Center for Nuclear Medicine, Clinics Hospital, Medicine Faculty, UDELAR, Montevideo, Uruguay
3 Uruguayan Center for Molecular Imaging, CUDIM, Montevideo, Uruguay
4 Center for Nuclear Medicine, Clinics Hospital, Medicine Faculty, UDELAR; Uruguayan Center for Molecular Imaging, CUDIM, Montevideo, Uruguay

Correspondence Address:
Enrique Gustavo Cuna
Dr. Américo Ricaldoni 2010, Montevideo,
Uruguay
Login to access the Email id


DOI: 10.4103/wjnm.WJNM_45_18

PMID: 31516368

Rights and Permissions

The aim of this study was quantitative comparison between 68Ga-Gallgas positron emission tomography (PET) and 99mTc-Technegas single photon emission computed tomography (SPECT) for lung ventilation function assessment in patients with moderate-to-severe obstructive pulmonary disease and to identify image-derived texture features correlating to the physiologic parameters. Five patients with moderate-to-severe chronic obstructive pulmonary disease with PET and SPECT lung ventilation scans were selected for this study. Threshold-based segmentations were used to compare ventilated regions between both imaging techniques. Histograms of both scans were compared to reveal main differences in distributions of radiotracers. Volumes of segmentation as well as 50 textural features measured in the pulmonary region were correlated to the forced expiratory volume in 1 s (FEV1) as the relevant physiological variable. A better peripheral distribution of the radiotracer was observed in PET scans for three out of five patients. A segmentation threshold of 27% and 31% for normalized scans, for PET and SPECT respectively, was found optimal for volume correlation with FEV1. A high correlation (Pearson correlation coefficient >0.9) was found between 16 texture features measured from SPECT and 7 features measured from PET and FEV1. Quantitative measurements revealed different tracer distribution in both techniques. These results suggest that tracer distribution patterns may depend on the cause of the pulmonary obstruction. We found several texture features measured from SPECT to correlate to FEV1.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed864    
    Printed61    
    Emailed0    
    PDF Downloaded130    
    Comments [Add]    

Recommend this journal