Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
  Home Print this page Email this page Small font sizeDefault font sizeIncrease font size Users Online: 1241  
ORIGINAL ARTICLE
Year : 2015  |  Volume : 14  |  Issue : 1  |  Page : 16-18

Determination of Organ Doses in Radioiodine Therapy using Monte Carlo Simulation


1 Department of Medical Physics and Medical Engineering, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
2 Department of Medical Radiation Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran

Correspondence Address:
Daryoush Shahbazi-Gahrouei
Department of Medical Physics and Medical Engineering, Isfahan University of Medical Sciences, Isfahan
Iran
Login to access the Email id


DOI: 10.4103/1450-1147.150517

PMID: 25709539

Rights and Permissions

Radioactive iodine treatment is a type of internal radiotherapy that has been used effectively for the treatment of differentiated thyroid cancer after thyroidectomy. The limit of this method is its affects on critical organs, and hence dosimetry is necessary to consider the risk of this treatment. Scope of this work is the measurement of absorbed doses of critical organs by Monte Carlo simulation and comparing the results with other methods of dosimetry such as direct dosimetry and Medical Internal Radiation Dose (MIRD) method. To calculate absorbed doses of vital organs (thyroid, sternum and cervical vertebrae) via Monte Carlo, a mathematical phantom was used. Since iodine 131 ( 131 I) emmits photon and beta particle, *F8 tallies, which give results in MeV were applied and the results were later converted to cGy by dividing by the mass within the cell and multiplying by 1.6E-8. The absorbed dose obtained by Monte Carlo simulations for 100, 150 and 175 mCi administered 131 I was found to be 388.0, 427.9 and 444.8 cGy for thyroid, 208.7, 230.1 and 239.3 cGy for sternum and 272.1, 299.9 and 312.1 cGy for cervical vertebrae. The results of Monte Carlo simulation method had no significant difference with the results obtained via direct dosimetry using thermoluminescent dosimeter-100 and MIRD method. Hence, Monte Carlo is a suitable method for dosimetry in radioiodine therapy.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1707    
    Printed57    
    Emailed0    
    PDF Downloaded405    
    Comments [Add]    

Recommend this journal