The role of routine whole volume SPECT reconstruction in comparison to cine raw data in the detection of extracardiac uptake on myocardial perfusion scans


1 Division of Nuclear Medicine, Groote Schuur Hospital, University of Cape Town, South Africa
2 Nuclear Medicine, Department of Medical Imaging and Clinical Oncology, Stellenbosch University and Tygerberg Hospital, Cape Town, South Africa

Date of Web Publication16-Jun-2011

Correspondence Address:
M Maharaj
Division of Nuclear Medicine, Groote Schuur Hospital, University of Cape Town
South Africa
Login to access the Email id


DOI: 10.4103/1450-1147.82111

PMID: 22034577

Rights and Permissions
   Abstract 

The objective of this study was to determine the role of routine whole volume reconstructed single-photon emission tomography (rSPECT) compared to cine raw data to detect extracardiac uptake of Sestamibi (MIBI). In a retrospective study, the myocardial perfusion studies of 426 patients were inspected separately for extracardiac uptake on cine raw data and rSPECT. The acquisition parameters for all the images were done according to departmental protocol. The whole volume SPECT data was selected and processed by HOSEM iterative reconstruction using the HERMES computer software system. The images were assessed by two observers, a student in training and a senior consultant nuclear medicine physician. The overall mean age and standard deviation of the 426 patients at the time of the study was 60 ΁ 12 years. Statistical analysis was performed using the Kappa and McNemars tests. The clinical significance of the extracardiac uptake was evaluated using hospital folders and /or laboratory results after viewing images. rSPECT detected 25 patients (5.9%) and cine raw data identified 18 patients (4.2%) with extracardiac uptake. All the areas of extracardiac uptake noted on cine raw data were seen on the rSPECT images. Only 21 of the 25 patients had complete 5-year clinical follow-up. The value of the clinical significance of the extracardiac uptake was limited due to the study being retrospective. The proportion of positives identified by rSPECT was significantly larger than those identified by cine raw data (P = 0.0082). Although our study demonstrates that rSPECT is more sensitive than cine raw data in detecting extracardiac uptake, it also shows that there is no benefit in routine whole volume rSPECT in daily clinical practice.

Keywords: Cine raw data, extracardiac uptake, myocardial perfusion single-photon emission tomography, Sestamibi


How to cite this article:
Maharaj M, Korowlay N A. The role of routine whole volume SPECT reconstruction in comparison to cine raw data in the detection of extracardiac uptake on myocardial perfusion scans. World J Nucl Med 2011;10:9-13

How to cite this URL:
Maharaj M, Korowlay N A. The role of routine whole volume SPECT reconstruction in comparison to cine raw data in the detection of extracardiac uptake on myocardial perfusion scans. World J Nucl Med [serial online] 2011 [cited 2020 Sep 24];10:9-13. Available from: http://www.wjnm.org/text.asp?2011/10/1/9/82111


   Introduction Top


Myocardial perfusion single-photon emission tomography (MPSPECT) imaging is a validated diagnostic technique, routinely used to evaluate myocardial perfusion in patients with suspected coronary artery disease. Three myocardial perfusion agents are commercially available and in widespread use: Thallium 201 Tl chloride, 99m Tc SestaMIBI (Cardiolite, Lantheus Medical Imaging, N. Billerica, MA, USA), and 99m Tc Tetrofosmin (Myoview, GE Healthcare, Amersham, UK). [1] 99m Tc SestaMIBI (MIBI) is used in the Department of Nuclear Medicine at Tygerberg Hospital.

Sestamibi was first described in 1984 by Jones et al. as a myocardial perfusion tracer. [2] In 1990, Delmon-Moingeon et al. described Sestamibi as an in vivo tumor imaging agent. [3] Although the exact uptake mechanisms into the myocardial and tumor cells are not well understood, it is postulated to be related to blood flow, blood residence time, and the cellular uptake due to passive influx of the lipophilic cation, driven by the plasma and mitochondrial membrane potentials generated in living cells. Elevated potentials are directly related to metabolic state. [4] MIBI is physiologically taken up by the salivary glands, thyroid, heart, liver, spleen, and skeletal muscle. There is physiological hepatobiliary and renal clearance. The advantages include a readily available kit which is easy to prepare and cost-effective for a large patient-base, and reasonable radiation dosimetry with good quality images from the 140-keV single gamma photon energy of 99m Tc.

There is a relationship of the increased incidence for tumor risk with increasing age. [5] It is not surprising that the incidence for detection of malignant lesions will increase on a MPSPECT corresponding to the increasing age at which the prevalence of cardiac diseases exists.

As the ultimate goal is the well-being of the patient, any available information should be examined and interpreted. [6],[7] MIBI has fortuitously been observed to show uptake in benign and malignant tumors including the lung, thyroid, brain, lymph node metastasis, bone and in breast cancer. [8],[9],[10],[11],[12],[13],[14],[15],[16],[17],[18],[19],[20],[21]

The routine evaluation of myocardial perfusion scans includes the reconstructed SPECT images localized just to the myocardium. The routine protocol for the evaluation of myocardial perfusion scans includes the inspection of the planar, cine raw data and the reconstructed SPECT images limited just to the myocardium. The reviewing of cinematic projections in order to detect extracardiac uptake has been recommended. [6],[20],[21],[22] Previously, whole volume reconstruction was only done when extracardiac uptake was noted on the planar or cine raw data images.


   Materials and Methods Top


The aim of the study was to determine the role of routine whole volume reconstructed single-photon emission tomography (rSPECT) compared to cine raw data to detect extracardiac uptake of Sestamibi (MIBI). This retrospective study was approved by the Ethics Committee of the Division of Research Development and Support at Stellenbosch University. A 1-day protocol was used in this department. The dose for the resting study was approximately two thirds more than the dose injected for the stress (dose range 740-1000 MBq). The resting study was performed approximately 3 hours after the stress study. The resting study images were only used due to the higher dose giving better image quality. The resting studies done from January 2002 to December 2002 in the Division of nuclear medicine were reviewed.

The departmental acquisition protocol was followed. The injection of MIBI was followed by a minimum waiting period of 60 minutes. The myocardial perfusion SPECT imaging was acquired using a dual-headed gamma camera (Elscint Helix Apex SPX) equipped with a low-energy, all-purpose, parallel-hole collimator. The SPECT data was acquired in list mode with 180° arc, either supine with a starting angle of 90° or prone with a starting angle of 270°. The cine raw data images were viewed in a thermal color scale.

The cine raw SPECT data of the resting MIBI scans were processed using HOSEM iterative reconstruction on the HERMES software system. The entire field of view of 40 cm by 50 cm was selected for reconstruction and a predefined reconstruction protocol was applied. The protocol was defined using 30 iterations and 4 subsets and the Butterworth filter was used with 0.900 cycles/cm and an order of 5. The rSPECT images were displayed in a gray color scale. The images were evaluated using three-dimensional localization with standard tomographic sections of the body (sagittal, coronal and transaxial) and then displayed in static transverse slices for further assessment.

The images were assessed by two observers, a student in training and a senior consultant nuclear medicine physician. The cine raw data and the rSPECT images were viewed separately to eliminate bias . Extracardiac uptake not as a result of normal biodistribution was considered abnormal. Statistical analyses were performed in consultation with the Centre for Statistical Consultation at the University of Stellenbosch. Analysis of the primary outcome variable was achieved by means of the Kappa statistic (tests for significance) for agreement and McNemar's test. Hospital folders and/or laboratory results of the patients found with extracardiac uptake were reviewed in order to evaluate the clinical significance of the extracardiac uptake. All identifying details such as the name and hospital number were not recorded on a data capture sheet or directly linked to the data set, maintaining patient confidentiality.


   Results Top


A total of 427 resting studies were assessed for extracardiac uptake. On completion of data collection and reconstruction, there were 426 cine raw data and 426 rSPECT images. One study was uninterpretable and excluded from the study. The study group of 426 patients had a mean age ± standard deviation of 60 ± 12 years. After reviewing all the images in the study group, only 25 patients were found to have extracardiac uptake. The mean age and standard deviation of the 25 patients were 60 ± 12 years.

Further analyses revealed that rSPECT detected 25 patients (5.9%) and cine raw data identified 18 patients (4.2%) with extracardiac uptake. The entire extracardiac uptake noted on cine raw data was seen on the rSPECT images.

A descriptive analysis of the 25 sites of extracardiac uptake was done. Focal uptake was seen in the left axilla (8 patients), right axilla (6 patients), retrosternal area (1 patient), in the region of the suprasternal notch (1 patient), in the left lung upper lobe (1 patient) and the thyroid (6 patients) [Table 1]. There was generalized inhomogeneous bone marrow uptake in two patients. A Kappa value of 0.8288 was observed, indicating a relatively strong agreement between the two methods with a P-value <0.0001. According to the McNemar's method, the proportion of positives identified by rSPECT was significantly larger than the proportion of positives identified by cine raw data (P = 0.0082).
Table 1: Imaging, sites of extracardiac uptake and clinical findings (n = 21)

Click here to view


Hospital folders and/or laboratory results of the patients found with extracardiac uptake were reviewed in order to assess the clinical significance of those extracardiac uptake findings. Folders and follow-up were not available in three patients and another patient died of cardiac complications soon after the study in 2002. These patients had focal uptake in the thyroid (1), left lung upper lobe (1), right (1) and left (1) axillae [Table 2].
Table 2: Imaging and sites of extracardiac uptake with no clinical follow-up (n = 4)

Click here to view


There were seven patients with extracardiac uptake identified only on rSPECT. One patient with a focus in the thyroid had a history of squamous cell carcinoma (the same year as the study) and basal cell carcinoma (2 years after the study). A second patient with a focus in the retrosternal region was diagnosed with pulmonary tuberculosis (PTB) in the left lung (a year after the study) with no complications. In three patients with uptake in the thyroid, left axilla and suprasternal notch area, the clinical follow-up did not reveal any malignancies or significant clinical illnesses, which would explain the extracardiac uptake. The remaining two patients were lost to follow-up.

Overall, the review of the clinical records, laboratory and histopathological findings in 21 patients revealed that 6 out of these 21 patients were diagnosed with malignancies over a 5-year period, following their cardiac examinations, revealing extracardiac uptake of Sestamibi. The sites of extracardiac uptake in these six patients included thyroid (n = 1), right axilla (n = 3) and bone marrow (n = 2). Except for one patient diagnosed with PTB diagnosed within a year of the study, the remaining 14 patients had no significant clinical incidences during the 5-year follow-up period.


   Discussion Top


Extracardiac uptake may be infrequent and incidentally detected when routinely assessing myocardial perfusion studies. The reported incidence for detection of extracardiac uptake on cine raw data was 1.2 and <1% according to the data published by Gedik [21] and Jones, [22] respectively. This study shows a higher incidence of extracardiac uptake of 4.2% on cine raw data and 5.9% on rSPECT.

Our study, like that of Gedik, [21] demonstrates that rSPECT provides more detailed anatomical correlation and better characterization of lesions, helping in defining the abnormality seen on cine raw data, and thereby obviating potential false-positive results. In our study, such areas included uptake around the mediastinum, particularly in regions occupied by the right atrium and ventricle as well as the great vessels. Other areas included variations in intensity of the salivary and thyroid glands due to asymmetrical positioning of the head and neck, increased activity in the left scapula due to the SPECT data being acquired from left posterior oblique (LPO) to right anterior oblique (RAO), and the injection site frequently resulting in prominent vessel visualization. In review of the patients' folders with axillary uptake, none were related to the injection site.

Six patients were diagnosed with malignancies during the 5-year follow-up. One patient had basal and squamous cell carcinomas, which were diagnosed in 2002 and 2004, respectively, both involving the left ear. This patient was treated with local radiotherapy and had no history of lymph nodes or spread of disease. This patient had uptake below the left thyroid lobe, only seen on rSPECT. A second patient had cervical carcinoma diagnosed in 2004, with uptake in the right axilla, seen on both images. A third patient was diagnosed with gastric carcinoma in 2004, had uptake in the right axilla, also seen on both images. A fourth patient had tubular adenoma of the colon, diagnosed in 2004, with uptake in the right axilla, seen on both images. Reviewing the patients' folders, it appears that the extracardiac uptake noted in the four patients mentioned above was unrelated to the patients' underlying pathology. A fifth patient had prostate carcinoma diagnosed in 2002 and a sixth patient was diagnosed with laryngeal carcinoma in 2004; both had uptake in the bone marrow, seen on both images. Despite the bone marrow uptake being seen on both cine raw data and rSPECT, it was visualized more clearly on rSPECT. In 2002, Wakasugi [23] found that MIBI accumulation attributed to bone marrow metastases may occur at an early stage, before the bone remodeling process in the surrounding bone can be detected on conventional bone scans, supporting the importance of our findings.

There are several limitations in this retrospective study. These are as follows: 1) the study being retrospective; 2) in review of the patients' folders, none of the 25 areas of extracardiac uptake were reported previously, as images were displayed and viewed on emulsion films; 3) immediate clinical workup of these patients could not be done; 4) the lack of follow-up of four patients, and the clinical significance could not be determined; and 5) physiological hepatobiliary excretion precluded the detection of abnormal uptake below the diaphragm.

Although not done in our study, it could be recommended that SPECT/CT has a potential role in localizing and characterizing possible abnormal uptake above and below the diaphragm. In view of the limited number of lesions detected in the study group, similar studies are needed to verify or corroborate this study.


   Conclusion Top


Although our study demonstrates that rSPECT is more sensitive than cine raw data in detecting extracardiac uptake, there is no benefit of routine whole volume rSPECT in daily clinical practice.

 
   References Top

1.Aaron L, Boucher C. Radiopharmaceutical agents for myocardial perfusion imaging. Circulation 2008;118:1668-74.  Back to cited text no. 1
    
2.Jones AG, Abrams MJ, Davison A, Brodack JW, Toothaker AK, Adelstein SJ, et al. Biological studies of a new class of Technetium complexes: The hexakis (alkylisonitrile) technetium (I) cations (abstract). Int J Nucl Med Biol 1984;11:225-34.  Back to cited text no. 2
[PUBMED]    
3.Delmon-Moingeon LI, Piwnica-Worms D, Van den Abbeele AD, Dolman BL, Davison A, Jones AG. Uptake of the Cation Hexakis (2-methoxyisobutylisonitrile)-Technetium-99m by human carcinoma cell lines in vitro. Cancer Res 1990;50:2198-202.  Back to cited text no. 3
    
4.Moretti JL, Hauet N, Caglar M, Rebillard O, Burak Z. To use MIBI or not to use MIBI? That is the question when assessing tumour cells. Eur J Nucl Med Mol Imaging 2005;32:836-42.  Back to cited text no. 4
[PUBMED]  [FULLTEXT]  
5.Armitage P, Doll R. The age distribution of cancer and a multi-stage theory of carcinogenesis. Int J Epidemiol 2004;33:1174-9.  Back to cited text no. 5
[PUBMED]  [FULLTEXT]  
6.Hesse B, Tägil K, Cuocolo A, Anagnostopoulos C, Bardiés M, Bax J, et al. EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology. Eur J Nucl Med Mol Imaging 2005;32:855-97.  Back to cited text no. 6
    
7.Gholamrezanezhad A, Mirpour S. An important but easily forgettable review: Extra-cardiac activity in myocardial perfusion scans. Int J Cardiovasc Imaging 2007;23:207-8.  Back to cited text no. 7
[PUBMED]  [FULLTEXT]  
8.Raza M, Panjrath G, Jain D. Unusual retrocardiac radiotracer uptake on MIBI perfusion images. J Nucl Cardiol 2004;11:e1-2.  Back to cited text no. 8
    
9.Duarte PS, Zhuang H, Blasbalg R, Aldighieri F, Martins LR, Alonso G. Hepatic cysts detected on myocardial perfusion scintigraphy. Clin Nucl Med 2001;26:468-9.  Back to cited text no. 9
[PUBMED]  [FULLTEXT]  
10.Aziz K, Jones S, Yasud T, Gewirtz H, Scott JA. Underreporting of abnormal extra-cardiac uptake on 99mTc-MIBI Myocardial Perfusion scan (abstract). J Nucl Cardiol 2004;11:S29.  Back to cited text no. 10
    
11.Kim SM, Bom HS, Song HC, Jeong HJ, Min JJ, Li MH, et al. Focal pulmonary uptake during Tc-99m myocardial perfusion SPECT imaging. Clin Nucl Med 2001;26:913-5.  Back to cited text no. 11
[PUBMED]  [FULLTEXT]  
12.Fisher C, Vehec A, Kashlan B, Longa G, Houpt L, Howe K, et al. Incidental detection of a malignant Hurthle cell carcinoma by Tc-99m sestamibi cardiac imaging. Clin Nucl Med 2000;25:469-70.  Back to cited text no. 12
[PUBMED]  [FULLTEXT]  
13.McBiles M, Lambert AT, Cote MG, Kim SY. Sestamibi parathyroid imaging. Semin Nucl Med 1995;25:221-34.  Back to cited text no. 13
[PUBMED]    
14.Fisher C, Vehec A, Kashlan B, Longa G, Lowell H. Incidental detection of skeletal uptake on sestamibi cardiac images in a patient with previously undiagnosed multiple myeloma. Clin Nucl Med 2000;25:213-4.  Back to cited text no. 14
    
15.Williams KA, Hill KA, Sheridan CM. Noncardiac findings on dual-isotope myocardial perfusion SPECT. J Nucl Cardiol 2003;10:395-402.  Back to cited text no. 15
[PUBMED]    
16.Lamont AE, Allison E, Joyce JM, Judith M, Grossman SJ, Stanley J. Acute cholecystitis detected on a 99m Tc- sestamibi myocardial imaging. Clin Nucl Med 1996;21:879.  Back to cited text no. 16
    
17.Chatziioannou SN, Alfaro-Franco C, Moore WH, Alanis-Williams L, Dhekne RD, Ford PV. The significance of incidental noncardiac findings. Texas Heart Inst J 1999;26:229-31.  Back to cited text no. 17
    
18.Aktolun C, Bayhan H. Tc-99m MIBI uptake in pulmonary sarcoidosis. Preliminary clinical results and comparison with Ga-67. Clin Nucl Med 1994;19:1063-605.  Back to cited text no. 18
[PUBMED]    
19.Slavin JD, Engin IO, Spencer RP. Retrocardiac uptake of Tc-99m sestamibi: Manifestation of a hiatal hernia. Clin Nucl Med 1998;23:239-40.  Back to cited text no. 19
    
20.Medolago G, Virotta G, Piti A, Tespili M, D'Adda F, Rottoli MR, et al. Abnormal uptake of technetium-99m hexakis-2-methoxyisobutylisonitrile in a primary cardiac lymphoma. Eur J Nucl Med 1992;19:222-5.  Back to cited text no. 20
    
21.Gedik GK, Ergün EL, Aslan M, Caner B. Unusual extra-cardiac uptake detected on myocardial perfusion single photon emission computed tomography studies with tc-99m sestamibi. Clin Nucl Med 2007;32:920-6.  Back to cited text no. 21
    
22.Jones SE, Aziz K, Yasuda T, Gewirtz H, Scott JA. Importance of systematic review of rotating projection images from Tc99m-sestamibi cardiac perfusion imaging for non-cardiac findings. Nucl Med Commun 2008;29:607-13.  Back to cited text no. 22
[PUBMED]  [FULLTEXT]  
23.Wakasugi S, Noguti A, Katuda T, Hashizume T, Hasegawa Y. Potential of 99mTc-MIBI for detecting bone marrow metastases. J Nucl Med 2002;43:596-602.  Back to cited text no. 23
[PUBMED]  [FULLTEXT]  



 
 
    Tables

  [Table 1], [Table 2]


This article has been cited by
1 Extracardiac Findings on Routine Echocardiographic Examinations
Mohamad Alkhouli,Paul Sandhu,Susan E. Wiegers,Pravin Patil,John Panidis,Amit Pursnani
Journal of the American Society of Echocardiography. 2014; 27(5): 540
[Pubmed] | [DOI]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
    Introduction
    Materials and Me...
    Results
    Discussion
    Conclusion
    References
    Article Tables

 Article Access Statistics
    Viewed3009    
    Printed302    
    Emailed0    
    PDF Downloaded563    
    Comments [Add]    
    Cited by others 1    

Recommend this journal